Product
ProductCurrent position > Product detail

Submersible electromagnetic flowmeter

『Submersible electromagnetic flowmeter』Related information(v cone flow meter|rotary gas meter|gallon meter|gear meter|metal tube rotameter|glass tube rotameter|nutating disk meter|transit time ultrasonic flow meter|wedge flow meter|pd meters|hydraulic flow meter|ultrasonic water flow meter|water flow meter|air flow meter|magnetic water flow meter|oxygen flow meter|gas flow meter|argon flow meter|air velocity meter|gasoline flow meter|fuel flow meter|ultrasonic water meter|digital water meter|nitrogen flow meter|solid flow meter|Oxygen tank flow meter|digital water flow meter|diesel fuel flow meter|steam flow meter|02 flow meter|compressed air flow meter|oil flow meter|liquid flow meter)

1. Technical parameters of electromagnetic flowmeter?

● Nominal Diameter Series DN (mm) Pipeline PTFE Lining: 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 Pipeline Rubber Lining: 40, 50, 65, 80, 100, 125, 150, 300, 400, 500, 500, 600 Pipeline Rubber Lining: 40, 50, 65, 80, 125, 250, 300, 400, 500, 500, 500, 500, 1200 Note: Special specifications can be customized ● Flow Direction Forward, Reverse, Net Flow Rate, Range Ratio: 150:1 Repeatability Error: ± 0.1% of Measurement Value ● Accuracy Class: 0.5 Class, 1.0 Class ● Temperature Tolerance of Tested Medium: Ordinary Rubber Lining: -20~+60 ℃ High Temperature Rubber Lining: -20~+90 ℃ PTFE Lining: -30~+100 ℃ High Temperature Type B Vinyl lining: -30~+180 ℃ ● Rated working pressure: Pipeline type: DN10—DN65:≤2.5Mpa, DN80—DN150:≤1.6Mpa, DN200—DN1200:≤1.0Mpa ● Flow measurement range: Flow measurement range: Flow velocity range is 0.3-15m/s ● Conductivity range: The conductivity of the measured fluid is ≥ 5 μ s/cm. Most media composed of water have a conductivity in the range of 200-800 μ s/cm, and electromagnetic flow can be used; ● Output current and load resistance: 4~20mA Fully isolated load resistance < 750 ohms Pulse Lao Tan Sen frequency 0-1KHZ Optoelectronic isolation OCT External power supply ≤ 35V Maximum collector current when conducting: 25mA ● Electrode material: Stainless steel containing molybdenum, titanium (Ti), tantalum (Ta), Hastelloy (H), platinum (Pt) or other special electrode materials ● Protection level: Submersible type: IP68, other types IP65 ● Power supply: 85~265V, 45~63HZ ● Straight pipe length: Pipeline type: Upstream ≥ 5DN, downstream ≥ 2DN ● Connection method: Flange connection is used

Submersible electromagnetic flowmeter
between the flowmeter and the piping, and the flange connection size should comply with the provisions of GB9119-88. ● Anti riot sign: mdllBT4 ● Environmental temperature: -25 ℃~+60 ℃ ● Relative temperature: 5%~95% ● Total power consumption: less than 200000

2. What are the methods for measuring river flow

It belongs to channel flow measurement. There are two types of open channel flow meters that can be used for multi-point measurement: weir type and trough type, PB trough method and submersible electromagnetic method. The comparisons are as follows: The OP chooses independently. Comparison of measurement methods: Weir method (thin walled weir), P-groove method, PB groove method, submersible electromagnetic method, applicable channel types, open channels, open channels, circular and concealed channels, open and concealed channels, flow detection structure characteristics, channel to be intercepted, simple structure of the detection piece, one section of the channel to be loaded into the groove, more complicated structure of the detection piece, one section of the channel to be loaded into the groove, more complicated structure of the detection piece, channel to be intercepted, detection piece as the body, diversion model, enlarged flow detection instrument, liquid level gauge, liquid level gauge, this instrument directly measures channel width, throat width or caliber, channel width: 450-8000, throat width: 25-240 (15200), caliber: 150-1800 (3000), cautious lifting diameter: 500-400 (600), flow or flow rate range: 15-40000 m/h, triangular weir small flow rectangular The flow rate in the weir is equal to the width of the weir, with a large flow rate of 30-15000 (33000) m/h, 20-2000 (4200) m/h, and 10-5000 m

『SILVER Official Website SERVICE』

Copyright2026SILVER E-Commerce